M41 Csörgő – 8bit MTB H0 Plux22
Sound sample
Project Information
- Optimised for the MTB H0 model equipped with a Plux22 connector.
- Designed for 8-bit ZIMO MX sound decoders.
- Recommended minimum decoder software version is 40.22.
- The factory default address is 3.
- Program CV8 = 8 to reset the decoder to the project defaults.
Function Assignment
Function mapping and CV settings can be modified.
-
F0 White marker lightsAffected function output: FA0v, FA0rDirection dependent
-
F1 Red lightsAffected function output: FA1, FA2Direction dependent
-
F2 HeadlightAffected function output: FA3Direction dependent, linked to F0
-
F3 Shunting modeAffected function output: FA0v, FA0r
- speed range reduced to ½
- reduces acceleration / braking times to ¼ of CV3 and CV4
- turns off red lights if enabled
- turns off the headlight if enabled
- triggers a short horn at start
-
F4 Short horn
-
F5 CoastingIdle sound regardless of set speed
-
F6 Engine to maximum RPMIndependent of set speed, even when stationary
-
F7 Long horn
-
F8 Sound on/offEngine on/off
-
F9 Driver’s cab lightAffected function output: FA4, FA5Direction dependent, switches off once the model starts moving
-
F10 Short whistle
-
F11 Long whistle
-
F12 Screw coupler down
-
F13 Screw coupler up
-
F14 Sanding
-
F15 Dispatcher whistle – newCall to readiness
-
F16 Dispatcher whistle – oldCall to readiness, departure
-
F17 CompressorAlso random sound
-
F18 Unused
-
F19 Wheel squeal in curves
-
F20 Heating
-
F21 Ventilator
-
F22 Unused
-
F23 Unused
-
F24 Unused
-
F25 Unused
-
F26 Mute sounds
-
F27 Volume down
-
F28 Volume up
Setting Maximum Speed
Use CV57 to adjust the maximum speed. CV5 would change the sound range, while CV57 leaves CV3/CV4 untouched.
Shunting Mode
All four marker lights switch on in shunting mode. Disable the feature with CV37 = 0 and re-enable it with CV37 = 3. The mode also turns off the red lights and headlight; override this by setting CV430 = 0 and back to CV430 = 3 when needed.
The mode halves the speed range and reduces acceleration/braking times to a quarter of the CV3/CV4 values. Disable it via CV124 = 16 or fully remove the timings with CV124 = 19. Default CV124 = 18.
A script triggers a short horn whenever the model starts in shunting mode if F3 and F8 are active and the speed is zero. CV837 = 8 disables it.
F5 Coasting vs F6 Engine to Maximum RPM
If both functions are active, coasting takes precedence.
Cabin Lighting
The driver’s cab light on F9 is script-controlled: it switches off when the model moves and turns back on after stopping. Disable it with CV837 = 8 if you prefer manual control.
For manual control without automatic switching, set CV43 = 96 together with CV837 = 8. Revert to the default by setting CV43 = 0 and CV837 = 0.
Compressor
The compressor offers two modes:
- Random activation when F8 is on (enabling F17 cancels it).
- Direct activation via F17 that requires F8 on and zero speed.
CV837 = 1 disables F17, CV837 = 2 disables the random mode, and CV837 = 3 disables both.
Curve Squeal
The effect needs F19 and F8 plus a speed between 14 and 100 (range 0–126). Set CV837 = 4 to disable it.
Custom Function Mapping
Remap functions via CV400 – CV428 if needed. The project itself does not rely on these CVs.
Decoder Reset
Program CV8 = 8 (or CV8 = 0) to restore the default settings.
Basic CV Settings in Project
- CV3 = 16
- CV4 = 14
- CV5 = 1
- CV6 = 1
- CV33 = 1
- CV34 = 2
- CV35 = 12
- CV36 = 16
- CV37 = 3
- CV38 = 0
- CV39 = 0
- CV40 = 0
- CV41 = 0
- CV42 = 0
- CV43 = 0
- CV44 = 0
- CV45 = 0
- CV46 = 0
- CV57 = 125
- CV105 = 145
- CV106 = 5
- CV124 = 18
- CV125 = 88
- CV126 = 88
- CV127 = 89
- CV128 = 90
- CV129 = 88
- CV130 = 89
- CV131 = 90
- CV190 = 3
- CV191 = 2
- CV254 = 212
- CV255 = 2
- CV256 = 6
- CV266 = 100
- CV339 = 6
- CV340 = 5
- CV374 = 5
- CV395 = 130
- CV396 = 27
- CV397 = 28
- CV430 = 3
- CV432 = 193
- CV433 = 195
- CV434 = 194
- CV435 = 195
- CV836 = 0
- CV837 = 0
Sound Sample Numbers
"Script" means that the corresponding sound is used inside a script outside the normal CV mapping. The number is provided for standalone use when the script is disabled.