- Universal sound project suitable for custom adjustments, especially light configurations.
- Designed for 8-bit ZIMO MX sound decoders.
- Recommended minimum decoder software version is 40.22.
- The factory default address is 3.
- Program CV8 = 8 to reset the decoder to the project defaults.
Function Assignment
Function mapping and CV settings can be modified.
-
F0 Position white lightsAffected function output: FA0v, FA0rDirection dependent
-
F1 Light reserveAffected function output: FA1
-
F2 Light reserveAffected function output: FA2
-
F3 Shunting mode
- speed range reduced to ½
- reduces acceleration / braking times to ¼ of CV3 and CV4
- triggers short horn at start
-
F4 Short horn
-
F5 CoastingIdle running sound regardless of set speed
-
F6 Engine acceleration to max RPMIndependent of set speed, even when stationary
-
F7 Long horn
-
F8 Sound on/offEngine
-
F9 Unused
-
F10 Short whistle
-
F11 Long whistle
-
F12 Uncoupling screw down
-
F13 Uncoupling screw up
-
F14 Sanding
-
F15 Dispatcher whistle - newCall to readiness
-
F16 Dispatcher whistle - oldCall to readiness, departure
-
F17 Compressor
-
F18 Switching sound setsLoaded / unloaded locomotive, when stationary
-
F19 Wheel squealing in curves
-
F20 Unused
-
F21 Unused
-
F22 Unused
-
F23 Unused
-
F24 Unused
-
F25 Unused
-
F26 Sound muting
-
F27 Volume decrease
-
F28 Volume increase
Setting Maximum Speed
Set the maximum speed via CV57. Changing CV5 alters the sound range, while CV57 leaves CV3/CV4 acceleration and braking times untouched.
Shunting Mode
Marker lights are disabled in shunting mode. Enable them together with the headlight by setting CV37 = 3.
The mode halves the speed range and reduces acceleration/braking times to a quarter of the CV3/CV4 values. Disable it via CV124 = 16; complete deactivation is possible with CV124 = 19. The default is CV124 = 18.
The script-triggered short horn requires F3, engine sound on via F8, and starting from zero speed. CV837 = 8 disables it (default CV837 = 0).
F5 Coasting vs F6 Engine to Maximum RPM
If both functions are active, coasting (F5) takes precedence.
Compressor
Two script-driven modes are available:
- Random activation while the engine sound (F8) is on; enabling F17 cancels it.
- Direct activation via F17 requiring F8 and zero speed.
CV837 = 1 disables F17, CV837 = 2 disables the random mode, and CV837 = 3 disables both.
Curve Squeal
Curve squeal requires F19 and F8 enabled, speed above 14 and below 100 (range 0–126). Set CV837 = 4 to disable the effect.
Custom Function Mapping
Use CV400 – CV428 for custom mapping if needed. The project itself does not rely on these CVs.
Decoder Reset
Program CV8 = 8 whenever you need to restore the default settings.
Basic CV Settings in Project
- CV3 = 16
- CV4 = 14
- CV5 = 1
- CV6 = 1
- CV29 = 14
- CV33 = 1
- CV34 = 2
- CV35 = 4
- CV36 = 8
- CV37 = 0
- CV38 = 0
- CV39 = 0
- CV40 = 0
- CV41 = 0
- CV42 = 0
- CV43 = 0
- CV44 = 0
- CV45 = 0
- CV46 = 0
- CV57 = 125
- CV105 = 145
- CV106 = 5
- CV124 = 18
- CV125 = 88
- CV126 = 88
- CV127 = 88
- CV128 = 88
- CV190 = 3
- CV191 = 2
- CV254 = 206
- CV255 = 1
- CV256 = 2
- CV266 = 100
- CV395 = 130
- CV396 = 27
- CV397 = 28
- CV836 = 0
- CV837 = 0